Technical data:
Housing: splash-proof, rugged
Connector: BNC plug and 8-pin-plug
Power: > 4000 measurements, 9-Volt-battery
Display: alphanumeric, reflective
Automatic switch-off: after 4 minutes
Dimensions: 180 × 83 × 55 mm
Weight: 300 g
Data logger function (optional): memory: ca. 2,620 measuring values / measuring rate: 1 min – 24 h
pH measurement
Measuring range: 0 – 14 рН
Resolution: 0.01 pH
Accuracy: 0.02 pH
Calibration: automatic at рН 4, pH 7. Additionally at pH 10 if required
Probe: gel-filled insertion probe
Probe length: 125 mm
Connector: BNC plug
Application: pH measurement directly in soils / substrates and in liquids
EC measurement
Measuring range: 0 – 200 mS
Resolution: 0.001 – 0.01 mS
Accuracy: ± 2 % from measured value
Calibration: automatic
Probe: plastic with platinum sensors
Probe length: 125 mm
Connector: 8-pin plug
Application: conductivity measurement in liquids, e.g. nutrient and stock solutions
Measurement of humidity, temperature and air pressure
Measurement of humidity, temperature and air pressure
Multi-probe
Probe: PVC, Ø 10 mm
Probe length: 250 mm
Sensors: FDR capacitive (moisture), NTC (temperature), bi-pol (salinity)
Temperature compensation: automatic
Connector: 8-pin plug
Applications: measurement of salinity, temperature, soil and substrate moisture
Activity measurement (salinity):
- Measuring range: 0 – 2.99 g/l of active salts
- Resolution: 0.01 g/l of active salts
- Calibration: factory calibration, stable
Temperature measurement:
- Measuring range: – 10 to +50°C
- Resolution: 0.1°C
Moisture measurement:
- Measuring range: 0.5% to 60%VWC
- Resolution: 0.1
- Calibration: 0: in air and 60%VWC: in water
HTP probe (humidity – temperature – air pressure)
Measuring range: 10 … 100 rH% / * 260 … 1260 hPa / – 20 … +80 °C
Resolution: 0.1 rH% / 0.1 hPa / 0.1 °C
Accuracy: 2% / 0.5 hPa / ±0.2%
Calibration: factory calibration
Connector: 8-pin plug
AM probe
Measuring range: 0 – 2.99 activity in g/l
Resolution: 0.01 activity in g/l
Calibration: factory calibration, stable
Probe: stainless steel with special 2-pol-sensor
Probe length: 250, 500 or 750 mm
Connector: 8-pin plug
Application: direct measurement of soil salinity
Soil moisture probe
Measuring range: 0 – 60 %VWC / -40 to +60°C
Accuracy: ± 3% / ± 0.5°C
Resolution: 0.1% / 0.1°C
Connector: 8-pin plug
Dimensions: H = 150 mm, Ø 60 mm
Application: moisture and temperature measurement directly in the soil or substarte
Data logger function
Measuring rate: 1 min – 24 h
Memory: ca. 2,620 measuring values